Hitachi Compute Blade 500 Series User Manual page 363

Hide thumbs Also See for Compute Blade 500 Series:
Table of Contents

Advertisement

Message
Consecutive power loss detected
during IOs on non-optimal write-
back volume/s.
This may have resulted in data
integrity issues.
Press 'X' to proceed.
DKM new key request failed;
controller security mode transition
was not successful.
Reboot server to retry request, or
press any key to continue
Drive security is enabled on this
controller and a pass phrase is
required.
Please enter the pass phrase
SAS 3004 iMR ROMB Configuration Utility
Hitachi Compute Blade 500 Series EFI User's Guide
Description
b
The LSI MegaRAID <HITACHI SAS 3004
.
iMR ROMB> Configuration Utility restarts.
Action 3:
If this message is displayed even though an
incorrect power-off or reboot has not been
executed during write operation, contact your
reseller or call maintenance personnel.
Cause:
An invalid power-off or reboot was executed
during a write operation.
Action 1:
a
Press the X key, and then press the Enter
.
key.
The following message appears: Critical
Message handling completed. Please exit.
b
Press the ESC key.
.
The selection window appears.
c
Press the Y key.
.
System startup continues.
Action 2:
If this message is displayed even though an
incorrect power-off or reboot has not been
executed during write operation, contact your
reseller or call maintenance personnel.
Cause:
The hard disk security functionality is not
supported.
Action 1:
a
Enter a character, and then press the Enter
.
key.
The following message appears: Critical
Message handling completed. Please exit.
b
Press the ESC key.
.
The selection window appears.
c
Press the Y key.
.
System startup continues.
Action 2:
If this message appeared, contact your reseller
or call maintenance personnel.
Cause:
The disk array controller parameter is incorrect.
Action:
If this message appeared, contact your reseller
or call maintenance personnel.