Rebuilding virtual drives

This subsection describes how to rebuild RAID 1 where a physical drive fails.
Changing and rebuilding physical drives are executed by maintenance
personnel. If you need to rebuild RAID configuration for some reason, follow
the procedure described below.
Note: Adding and changing internal options in the system unit are executed
by maintenance personnel. Do not remove the unit cover and not attach or
detach internal options by yourself. Work performed by unqualified persons
can lead to injuries or system failure because electronic devices are densely
implemented on the system unit.
Note: Make sure to back up data before rebuilding virtual drives. If not, any
error in executing the procedure may corrupt data.
Note:
Rebuild can be executed only with RAID 1 with redundancy.
The procedure described in this section is premised on that the faulty
physical drive has been replaced with a new one.
1
Start the utility referring to
.
2
Find a physical drive with Fault LED lighting orange and remove it.
.
No. LED name
1
2
3
Wait one minute or longer after removing the physical drive. Then, attach
.
a new one.
Note: Make sure to wait one minute or longer before attaching a new
physical drive. If not, the newly attached physical drive may not be
properly recognized.
4
On Configuration Options window, select Drive Management and press
.
Enter.
5
Drive Management window appears. Select Select Drive Operations and
.
press Enter.
Status
Active LED
Blinks green
Fault LED
Lights orange
LSI Software RAID Configuration Utility for disk arrays
Hitachi Compute Blade 500 Series EFI User's Guide
Starting the utility on page
Description
Blinks when the drive is accessed.
Blinks on the source of Rebuild in rebuilding.
An error occurred in the drive.
6-4.