Unrecoverable Error. Please check the SDRAM
connection. If problems persist contact Tech
Support.
This is a TEST message. Press any key to ignore it,
or wait 5 seconds. No further action is required.
Press any key to continue, or C to load the
configuration utility.
This firmware is an ALPHA version. It has not
completed all validation.
This firmware is a BETA version. It has not
completed all validation.
This firmware is a TEST version. It has not
completed any validation.
The firmware version inconsistency was detected.
The adapter was recovered, but cached data was
lost. Press any key to continue or press C to load
the configuration utility.
Firmware Failed Validation. Adapter needs to be
reflashed.
The most recent configuration command could not
be committed and must be retried. Press any key
to continue, or press C to load the configuration
utility.
Previous configuration cleared or missing.
Importing configuration created on X/Y X:Y Press
any key to continue or press C to load the
configuration utility.
An enclosure was found that contains both SAS
and SATA drives, but this controller does not allow
mixed drive types in a single enclosure. Correct
the problem and restart your system. Press any
key to continue or press C to load the configuration
utility.
SAS drives were detected, but this controller does
not support SAS drives. Remove the SAS drives
and restart your system. Press any key to continue
or press C to load the configuration utility.
SATA drives were detected, but this controller does
not support SATA drives. Remove the SATA drives,
and restart your system.
Press any key to continue or press C to load the
configuration utility.
Raid Key Missing. Please check the Raid Key
connection. If problems persist contact Tech
Support.
MegaRAID WebBIOS for storage expansion blades
Hitachi Compute Blade 500 Series EFI User's Guide
Description
When this message is displayed,
contact your reseller or call
maintenance personnel.
When this message is displayed,
contact your reseller or call
maintenance personnel.
When this message is displayed,
contact your reseller or call
maintenance personnel.
When this message is displayed,
contact your reseller or call
maintenance personnel.
When this message is displayed,
contact your reseller or call
maintenance personnel.
Disk array configuration information
was cleared or not found. When this
message is displayed, contact your
reseller or call maintenance
personnel.
The disk array controller is operated
by incorrect parameters. When this
message is displayed, contact your
reseller or call maintenance
personnel.