Hitachi Compute Blade 500 Series User Manual page 371

Hide thumbs Also See for Compute Blade 500 Series:
Table of Contents

Advertisement

Message
Some configured disks have been
removed from your system, or are
no longer accessible.
Check your cables and also ensure
all disks are present.
Press any key to continue or press
C to load the configuration utility.
The cache contains dirty data, but
some VDs are missing.
The cached data cannot be written
to the disk.
If this is an unexpected error, then
power off your system and check
your cables to ensure all disks are
present.
If you continue, the data in the
cache is permanently discarded.
Press X to acknowledge and
permanently destroy the cached
data.
The controller's I/O processor has
a fault that can potentially cause
data corruption.
Your controller needs replacement.
Contact your system support.
Press Y to acknowledge
SAS 3004 iMR ROMB Configuration Utility
Hitachi Compute Blade 500 Series EFI User's Guide
Description
Cause:
A physical drive that has logical drive
configuration information is not recognized.
Action 1:
a
Enter a character, and then press the Enter
.
key.
The following message appears: Critical
Message handling completed. Please exit.
b
Press the ESC key.
.
The selection window appears.
c
Press the Y key.
.
System startup continues.
Action 2:
a
Press the C key, and then press the Enter
.
key.
b
The LSI MegaRAID <HITACHI SAS 3004
.
iMR ROMB> Configuration Utility restarts.
Action 3:
If this message is displayed even though the
physical drive is properly mounted, contact your
reseller or call maintenance personnel.
Cause:
An invalid power-off or reboot was executed
during a write operation.
Action 1:
a
Press the X key, and then press the Enter
.
key.
The following message appears: Critical
Message handling completed. Please exit.
b
Press the ESC key.
.
The selection window appears.
c
Press the Y key.
.
System startup continues.
Action 2:
If this message is displayed even though an
incorrect power-off or reboot has not been
executed during write operation, contact your
reseller or call maintenance personnel.
Cause:
An error occurred in the processor of the disk
array controller.
Action 1:
a
Press the Y key, and then press the Enter
.
key.
The following message appears: Critical
Message handling completed. Please exit.