Error Messages For The Scsi Utility - Hitachi VisionBase 8450H Product Manual

Table of Contents

Advertisement

Ch 4: System Environment Settings
The settings for SCSI devices are shown below. (Continued)

Error Messages for the SCSI Utility

At the time of system startup, the following messages can be issued by SCSI BIOS. Check the message and take
corrective action if necessary.
Message:
Error accessing NVRAM, system may fail boot
Explanation:
NVRAM read error. The NVRAM might be damaged.
Message:
Failed, reverting all device to narrow
Explanation:
An error occurred at wide negotiation, so processing is performed with the SCSI bus width
switched to 8-bit mode. It is possible that the target-side firmware is faulty.
Message:
VelifyElTorito: XXXXXXXX Failed
Explanation:
An error occurred while booting CD-ROM according to the El Torito specifications.
The media might be damaged.
Message:
Device has an unsupported sector size
Explanation:
The sector size of the connected SCSI device is unsupported. Use an SCSI device with proper
sector size.
Message:
ERROR! Device is not responding to a read capacity
Explanation:
The connected SCSI device did not respond to the READ CAPACITY command.