Hitachi Compute Blade 500 Series User Manual page 372

Hide thumbs Also See for Compute Blade 500 Series:
Table of Contents

Advertisement

The following VDs have missing
disks:
If you proceed (or load the
configuration utility), these VDs is
marked OFFLINE and are
inaccessible.
Check your cables and ensure all
disks are present.
Press any key to continue or press
C to load the configuration utility.
The firmware version inconsistency
was detected.
The adapter was recovered, but
cached data was lost.
Press any key to continue or press
C to load the configuration utility.
5-64
Message
SAS 3004 iMR ROMB Configuration Utility
Hitachi Compute Blade 500 Series EFI User's Guide
Description
b
Press the ESC key.
.
The selection window appears.
c
Press the Y key.
.
System startup continues.
Cause:
The logical drive is set to Offline because some
physical drives are not recognized.
Action 1:
a
Enter a character, and then press the Enter
.
key.
The following message appears: Critical
Message handling completed. Please exit.
b
Press the ESC key.
.
The selection window appears.
c
Press the Y key.
.
System startup continues.
Action 2:
a
Press the C key, and then press the Enter
.
key.
b
The LSI MegaRAID <HITACHI SAS 3004
.
iMR ROMB> Configuration Utility restarts.
Action 3:
If this message is displayed even though the
physical drive is properly mounted, contact your
reseller or call maintenance personnel.
Cause:
An inconsistency in firmware versions was
detected.
Action 1:
a
Enter a character, and then press the Enter
.
key.
The following message appears: Critical
Message handling completed. Please exit.
b
Press the ESC key.
.
The selection window appears.
c
Press the Y key.
.
System startup continues.
Action 2:
a
Press the C key, and then press the Enter
.
key.
b
The LSI MegaRAID <HITACHI SAS 3004
.
iMR ROMB> Configuration Utility restarts.
Action 3:
If this message appeared, contact your reseller
or call maintenance personnel.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents