Hitachi Compute Blade 500 Series User Manual page 302

Hide thumbs Also See for Compute Blade 500 Series:
Table of Contents

Advertisement

Cache data was lost because of an unexpected
power-off or reboot during a write operation, but
the adapter has recovered. This could be because
of memory problems, bad battery, or you may not
have a battery installed. Press any key to continue
or press C to load the configuration utility.
The memory/battery problems were detected. The
adapter was recovered, but cached data was lost.
Press any key to continue or press C to load the
configuration utility.
Cache data was lost, but the controller has
recovered. This could be due to the fact that your
controller had protected cache after an unexpected
power loss and your system was without power
longer than the battery backup time. Press any key
to continue or press C to load the configuration
utility.
The cache contains dirty data, but some VDs are
missing. The cached data cannot be written to the
disk. If this is an unexpected error, then power off
your system and check your cables to ensure all
disks are present. If you continue, the data in the
cache will e permanently discarded. Press X to
acknowledge and permanently destroy the cached
data.
Foreign configurations found on adapter. Press any
key to continue or press C to load the configuration
utility.
FW package
The battery hardware is missing or malfunctioning,
the battery is unplugged, or the battery could be
fully discharged. If you continue to boot the
system, the battery-backed cache will not function.
If the battery is connected and has been allowed to
charge for 30 minutes and if this message
continues to appear, contact technical support for
assistance. Pres D to disable this warning (if your
controller does not have a battery).
The battery hardware is missing or malfunctioning,
the battery is unplugged, or the battery could be
fully discharged. If you continue to boot the
system, the battery-backed cache will not function.
If the battery is connected and has been allowed to
charge for 30 minutes and if this message
4-92
Table 4-25 BIOS messages
Message
MegaRAID WebBIOS for storage expansion blades
Hitachi Compute Blade 500 Series EFI User's Guide
Description
If these messages are displayed
even though an incorrect power-off
or reboot has not been executed
during write operation, contact your
reseller or call maintenance
personnel.
A hard disk with a different
configuration from the disk array
configuration in the disk array
controller was detected.
See
Disk with foreign configuration
on page
4-89.
This shows the firmware package
version. You do not need to take
any action.
Cache backup module information is
not set correctly.
Press the [D] key while this
message is displayed.
If this key operation does not
recover the situation, contact your
reseller or call maintenance
personnel.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents