Allied Telesis AT-AR3050S Command Reference Manual page 460

Next-generation firewall
Hide thumbs Also See for AT-AR3050S:
Table of Contents

Advertisement

S
T
C
PANNING
REE
OMMANDS
-
SHOW SPANNING
TREE
Output
Figure 13-2: Example output from show spanning-tree in RSTP mode
awplus#show spanning-tree
% 1: Bridge up - Spanning Tree Enabled
% 1: Root Path Cost 0 - Root Port 0 -
% 1: Forward Delay 15 - Hello Time 2 - Max Age 20
% 1: Root Id 80000000cd24ff2d
% 1: Bridge Id 80000000cd24ff2d
% 1: last topology change Thu Jul 26 02:06:26 2007
% 1: portfast bpdu-filter disabled
% 1: portfast bpdu-guard disabled
% 1: portfast errdisable timeout disabled
% 1: portfast errdisable timeout interval 300 sec
%
port1.0.1: Port 5001 - Id 8389 - Role Disabled - State Discarding
%
port1.0.1: Designated Path Cost 0
%
port1.0.1: Configured Path Cost 20000000
%
port1.0.1: Designated Port Id 8389 - Priority 128
%
port1.0.1: Root 80000000cd24ff2d
%
port1.0.1: Designated Bridge 80000000cd24ff2d
%
port1.0.1: Message Age 0 - Max Age 20
%
port1.0.1: Hello Time 2 - Forward Delay 15
port1.0.1: Forward Timer 0 - Msg Age Timer 0 - Hello Timer 0 - topo change 
%
timer 0
%
port1.0.1: forward-transitions 0
%
port1.0.1: Version Rapid Spanning Tree Protocol - Received None - Send STP
%
port1.0.1: No portfast configured - Current
%
port1.0.1: portfast bpdu-guard
%
port1.0.1: portfast bpdu-filter default
%
port1.0.1: no root guard configured
%
port1.0.1: Configured Link Type point-to-point - Current
%
%
port1.0.2: Port 5002 - Id 838a - Role Disabled - State Discarding
%
port1.0.2: Designated Path Cost 0
%
port1.0.2: Configured Path Cost 20000000
%
port1.0.2: Designated Port Id 838a - Priority 128
%
port1.0.2: Root 80000000cd24ff2d
%
port1.0.2: Designated Bridge 80000000cd24ff2d
%
port1.0.2: Message Age 0 - Max Age 20
%
port1.0.2: Hello Time 2 - Forward Delay 15
port1.0.2: Forward Timer 0 - Msg Age Timer 0 - Hello Timer 0 - topo change 
%
timer 0
%
port1.0.2: forward-transitions 0
%
port1.0.2: Version Rapid Spanning Tree Protocol - Received None - Send STP
%
port1.0.2: No portfast configured - Current
%
port1.0.2: portfast bpdu-guard
%
port1.0.2: portfast bpdu-filter default
%
port1.0.2: no root guard configured
%
port1.0.2: Configured Link Type point-to-point - Current
Output
Figure 13-3: Example output from show spanning-tree
C613-50077-01 REV A
Bridge Priority 32768
- Add type Explicit ref count 1
default
- Current portfast bpdu-guard off
- Current portfast bpdu-filter off
- Current root guard off
- Add type Explicit ref count 1
default
- Current portfast bpdu-guard off
- Current portfast bpdu-filter off
- Current root guard off
Command Reference for AT-AR3050S
AlliedWare Plus™ Operating System - Version 5.4.5-2.x
-
portfast off
shared
-
portfast off
shared
460

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents