L
C
OGGING
OMMANDS
(
)
LOG MONITOR
FILTER

log monitor (filter)

Overview
This command creates a filter to select messages to be sent to the terminal when
the terminal monitor command is given. Selection can be based on the
priority/severity of the message, the program that generated the message, the
logging facility used, a sub-string within the message or a combination of some or
all of these.
log monitor [level <level>] [program <program-name>] [facility
Syntax
<facility>] [msgtext <text-string>]
no log monitor [level <level>] [program <program-name>]
[facility <facility>] [msgtext <text-string>]
Parameter
Description
level
Filter messages by severity level.
<level>
The minimum severity of message to send. The level can be specified as one of the following
numbers or level names, where 0 is the highest severity and 7 is the lowest severity:
0|emergencies
1|alerts
2|critical
3|errors
4|warnings
5|notices
6|informational
7|debugging
program
Filter messages by program. Include messages from a specified program.
C613-50077-01 REV A
System is unusable
Action must be taken immediately
Critical conditions
Error conditions
Warning conditions
Normal, but significant, conditions
Informational messages
Debug-level messages
Command Reference for AT-AR3050S
AlliedWare Plus™ Operating System - Version 5.4.5-2.x