AAA C
OMMANDS
-
AAA LOGIN FAIL
DELAY
aaa login fail-delay
Overview
Use this command to configure the minimum time period between failed login
attempts. This setting applies to login attempts via the console, SSH and Telnet.
Use the no variant of this command to reset the minimum time period to its default
value.
Syntax
aaa login fail-delay [<1-10>]
no aaa login fail-delay [<1-10>]
Default
1 second
Mode
Global configuration
Example
To apply a delay of at least 5 seconds between login attempts, use the following
commands:
awplus#
awplus(config)#
Related
aaa authentication login
Commands
C613-50077-01 REV A
Parameter
Description
<1-10>
The minimum number of seconds required between login
attempts
configure terminal
aaa login fail-delay 5
Command Reference for AT-AR3050S
AlliedWare Plus™ Operating System - Version 5.4.5-2.x
1567