4. MECHANICAL SYSTEM
B. Potential Sensor Assembly
1. Removing the Potential Sensor Assembly
1) Remove the blank exposure lamp assembly
from the copier. (p. 4-63)
2) Remove the two mounting screws q, and
remove the potential sensor assembly from
the blank exposure lamp together with the sup-
port plate.
1
Figure 4-517
Caution:
You need not adjust the position of the
potential sensor. When replacing the poten-
tial sensor, be sure to replace it together
with the potential measurement PCB.
(Check to make sure that the potential sen-
sor and the potential measurement PCB
have the same number.)
4-70
COPYRIGHT © 1996 CANON INC.
C. Primary Charging Assembly
1. Removing the Primary Charging Assembly
1) Open the front doors.
2) Slide out the duplexing unit, and remove the
process cover.
3) Loosen the mounting screw q, and slide the
charging assembly stopper w to the left.
4) Disconnect the connector e, and pull out the
primary charging assembly r slowly.
1
CANON NP6085 REV.0 JULY 1996 PRINTED IN JAPAN (IMPRIME AU JAPON)
3
4
2
Figure 4-518