Remove active filter
Remove active filter
Caution:
The components in the fuser station reach a surface temperature of
approximately 230
Do not touch any parts behind the safety covers (see
information signs on page
Wear heat protection gloves when working with fuser station components.
To remove the active filter
[190]
Proceed as follows:
1.
If the printing system has not yet stopped, click the 'Stop' button:
2.
Select the 'VarioStream' 'Changing consumables' 'Replace active filter'
menu on the operator panel.
3.
Click the 'OK' button to start the procedure.
Information on the icons displayed on the operator panel under
'Work-steps': See
4.
Open the side door of the fuser station.
[456]
5.
346
Chapter 9 Replacing expendables
o
C. Touching the components can cause burns.
33).
Explanation of icons on page
Warning and
118.
To open, turn the knob of the
oiling unit to the left and swivel
up the oiling unit.