Cause
Environment
sensor
CPU PCB
Photosensitive
drum
Potential sensor
Photosensitive
drum
CPU PCB
COPYRIGHT © 2002 CANON INC.
Step
19
Check the temperature and
humidity in service mode
(COPIER>DISPLAY>ANALOG>
TEMP/HUM). Are the readings
normal?
20
Is the photosensitive drum
grounded properly?
21
Clean the potential sensor. Is the
problem corrected?
22
Replace the photosensitive drum. Is
the problem corrected?
CANON CLC1100/1130/1150/1160/1180 REV.2 FEB. 2002 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 13 TROUBLESHOOTING
Checks
Yes/No
Action
NO
Check the environment
sensor according to the
instructions under
7.
YES
Replace the CPU PCB.
(After replacement,
execute the work under
II. H. 1.)
Turn off and then on the
power switch; if the
error is indicated once
again, go to step 2.
NO
Ground the drum
properly.
YES
End.
YES
End.
NO
Replace the CPU PCB.
(After replacement,
execute the work under
II. H. 1.)
Turn off and then on the
power switch; if the
error is indicated once
again, go to step 2.