Canon 1130 Service Manual page 245

Color laser copier
Hide thumbs Also See for 1130:
Table of Contents

Advertisement

CHAPTER 6 IMAGE FORMATION SYSTEM
• When inserting the photosensitive drum cleaner unit into the copier, be sure to
put the cleaner unit in horizontal direction in relation to the copier's rails, and
make sure that it will not slide off the rails.
• When mounting the photosensitive drum cleaner unit, secure the cleaner
unit with a screw [3]; then, turn the blade releasing lever [2]
counterclockwise (locking direction), and check to make sure that the screw
has been tightened fully.
• Do not turn the blade releasing lever counterclockwise (locking direction)
before putting back the cleaner unit.
If you locked the cleaner unit in position by mistake, release it; then, be sure to
check that both edges of the scoop-up sheet is normal.
2. Replacing the Photosensitive Drum
Cleaner Blade
When removing the blade, be sure to detach the end seal; moreover, be sure to
attach the end seal after mounting back the blade.
You can remove the blade without detaching the end seal, but failure to
detach the end seal can lead to image faults.
1) Remove the photosensitive drum cleaner
unit.
2) Remove the screw [1], and detach the
photosensitive drum cleaner unit upper
cover [2].
3) Remove the screw [3] (one each), and
detach the end seal[4].
6-78
COPYRIGHT © 2002 CANON INC.
[1]
CANON CLC1100/1130/1150/1160/1180 REV.2 FEB. 2002 PRINTED IN JAPAN (IMPRIME AU JAPON)
[2]
Figure 6-667
[4]
[3]
Figure
6-668a
[1]
[4]
[3]

Hide quick links: