The nip width is correct if as indicated
in the table. Otherwise, turn the
adjusting nut [1] to make adjustments.
b and c are points 10 to 15
mm from the edges of pa-
per.
B. Fixing Cleaner Assembly
1. Removing the Fixing Upper
Cleaning Belt
1) Open the front cover.
2) Remove the fixing cover.
3) Slide out the transfer drum frame.
4) Remove the two screws, and detach the
fixing upper cover.
5) Remove the two screws [1], and detach
the fixing upper cleaner assembly [2].
6) Remove the two screws [3], and remove
the two bushings [4]; then, detach the
fixing upper cleaning belt.
COPYRIGHT © 2002 CANON INC.
CANON CLC1100/1130/1150/1160/1180 REV.1 FEB. 2002 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 8 FIXING SYSTEM
(feeding direction)
Dimen-
sion
a
b-c
b-a
c-a
*Make sure both upper and lower rollers
are adequately heated.
Table 8-421
[1]
Figure 8-422
[4]
[3]
Figure 8-423
b
Center of
a
paper
c
Standard*
7.3 0.5 mm
0.5 mm or less
0.5 mm or less
[2]
[1]
8-21