Canon 1130 Service Manual page 165

Color laser copier
Hide thumbs Also See for 1130:
Table of Contents

Advertisement

CHAPTER 6 IMAGE FORMATION SYSTEM
E071
ITOP sensor error
Detail
code
1102
1103
1104
1105
1106
1107
1108
1201
1202
1203
1204
1205
1206
1207
1208
6-6
COPYRIGHT © 2002 CANON INC.
The signal of the side B sensor (rising edge) is generated 10 ms earlier
than normal after the signal of the SP-C (rising edge) has been generated.
The signal of the SP-C (rising edge) is generated 10 ms earlier than
normal after the signal of the side B sensor (falling edge) has been
generated.
The signal of the SP-C (falling edge) is generated 10 ms earlier than
normal after the signal of the side B sensor (rising edge) has been
generated.
The signal of the side A sensor (rising edge) is generated 10 ms earlier
than normal after the signal of the SP-C (falling edge) has been
generated.
The signal of the A side sensor (falling edge) is generated 10 ms earlier
after the signal of the SP-D (rising edge) has been generated.
The signal of the SP-D (rising edge) is generated 10 ms earlier than
normal after the signal of the side A sensor (rising edge) has been
generated.
The signal of the SP-D (rising edge) is generated 10 ms earlier than
normal after the signal of the side A sensor (falling edge) has been
generated.
The signal of the side B sensor (falling edge) is generated 10 ms later
than normal after the signal of the SP-D (falling edge) has been
generated.
The signal of the side B sensor (rising edge) is generated 10 ms later
than normal after the signal of the SP-C (rising edge) has been generated.
The signal of the SP-C (rising edge) is generated 10 ms later than normal
after the signal of the side B sensor (falling edge) has been generated.
The signal of the SP-C (falling edge) is generated 10 ms later than
normal after the signal of the side B sensor (rising edge) has been
generated.
The signal of the side A sensor (rising edge) is generated 10 ms later
than normal after the signal of the SP-C (falling edge) has been
generated.
The signal of the side A sensor (falling edge) is generated 10 ms later
than normal after the signal of the SP-D (rising edge) has been
generated.
The signal of the SP-D (rising edge) is generated 10 ms laser than
normal after the signal of the side A sensor (rising edge) has been
generated.
The signal of the SP-D (rising edge) is generated 10 ms later than normal
after the signal of side A sensor (falling edge) has been generated.
SP-C:
Signal plate C.
SP-D:
Signal plate D.
CANON CLC1100/1130/1150/1160/1180 REV.2 FEB. 2002 PRINTED IN JAPAN (IMPRIME AU JAPON)