12
The copy has a fixing fault.
Cause
Fixing upper/
lower roller
Fixing heater
Oil applying
mechanism
Insulating bush,
bearing
Nip
Thermistor
COPYRIGHT © 2002 CANON INC.
Step
1
Is the problem noted in paper
feeding direction?
2
Does the heater (H1, H2) turn on
immediately after power-on?
3
Is the upper roller of the fixing
assembly coated with a uniform
layer of oil?
4
Are the insulating bush and the
bearing mounted properly?
5
Is the nip of the upper roller and
the lower roller of the fixing
assembly as indicated?
CANON CLC1100/1130/1150/1160/1180 REV.2 FEB. 2002 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 13 TROUBLESHOOTING
Checks
Yes/No
Action
YES
1. Check the upper
roller and the lower
roller of the fixing
assembly for
scratches.
2. Check the separation
claws to see if they
are mounted
properly.
NO
See
IV.
54..
NO
• Check the oil applying
assembly.
• Check the mechanism
used to supply oil
from the oil case.
NO
Mount the parts
properly.
NO
Adjust the nip.
YES
Check the thermistor for
a fault.
13-85