CHAPTER 6 IMAGE FORMATION SYSTEM
15) Pour the developer into the developing
assembly.
•
Try rotating the developer case slowly
to avoid spilling.
16) When done, press the Stop key to end the
operation.
17) Disconnect the connector [3], and free its
harness from the edge saddle; then,
remove the screw [4], and detach the
black toner concentration sensor unit.
6-72
COPYRIGHT © 2002 CANON INC.
CANON CLC1100/1130/1150/1160/1180 REV.2 FEB. 2002 PRINTED IN JAPAN (IMPRIME AU JAPON)
Figure 6-650
[3]
[4]
CLC1100/1120/1130/1150
[3]
[4]
CLC1140/1160/1180
Figure 6-651