1. If
2. When
4. Removing the ATR Sensor of the Y/
M/C Developing Assembly
1) Remove the Y/M/C developing assembly.
2) Remove the screw [1], and slide the
developing blade cover [2] to the right to
remove. (In the case of the Y developing
assembly, slide it to the left.)
3) Remove the four screws [3], and
disconnect the connector [4]; then,
remove the developing blade unit.
When assembling the
parts, force down the
developing blade unit, and
screw it in place.
4) Remove the three screws [5], and detach
the ATR sensor [6].
If you have replaced the
ATR sensor, be sure to
replace the developer and
select the appropriate
concentration in service
mode.
COPYRIGHT © 2002 CANON INC.
you
have
disconnected
connector
when
removing the Y/M/C
developing assembly,
be sure to clean the
inside of the ATR
sensor connector.
mounting
developing assembly to
the copier, be sure to
dry
wipe
its
bias
electrode with lint-free
paper in advance to
prevent
developing
faults.