A. Original Exposure System
1. Removing the Scanning Lamp
1) Remove the vertical side plate.
2) Remove the copyboard glass.
3) Remove the standard white plate cover.
4) Remove the screw [1], and detach the
right stay [2].
5) Remove the three screws [3], and detach
the anti-reflection plate [4].
6) Shift the scanning lamp to where the right
stay [2] was found. Turning a flat-blade
screwdriver in the direction of the arrow
[5], open the electrode plate in the
direction of the arrow [6] to detach the
scanning lamp.
·
Do not work if the
surface of the scanning
lamp is hot.
·
Do not leave fingerprints
on the surface of the
scanning lamp.
·
Dry wipe the surface of
the scanning lamp if it is
soiled.
2. Orienting the Scanning Lamp
Fit the scanning lamp so that the
protrusion [1] at its center is in the direction of
the arrow, and its side with a logo marking is
toward the rear.
Do not touch the surface of
the scanning lamp when
mounting it.