E. Drive Assembly
1. Removing the Fixing Motor (M5)
1) Remove the rear cover.
2) Remove the screw, and open the CPU
PCB.
3) Remove the fixing motor cover. (Pull it to
the front while opening it upward and
downward.)
4) Loosen the two screws [1].
5) Disconnect the two connectors [2], and
remove the two screws [3]; then, detach
the fixing motor together with its PCB.
2. Points to Note When Replacing the
Oil Pump
The oil pump may be replaced without
any adjustment. However, be sure to keep a
paper rag or the like against it to stop oil
pouring out when the tube is removed.
3. Adjusting the Fixing Upper/Lower
Solenoid
Make adjustments so that the stroke [A] of
the solenoid is as follows:
• Upper fixing solenoid: 3 ±0.2 mm
• Lower fixing solenoid: 4 ±0.2 mm
COPYRIGHT © 2002 CANON INC.
CANON CLC1100/1130/1150/1160/1180 REV.2 FEB. 2002 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 8 FIXING SYSTEM
[2]
Figure 8-437
Figure 8-438
[3]
[1]
Solenoid
8-27