Mounting The Fixing Upper Cleaning Belt - Canon 1130 Service Manual

Color laser copier
Hide thumbs Also See for 1130:
Table of Contents

Advertisement

CHAPTER 8 FIXING SYSTEM
2. Mounting the Fixing Upper
Cleaning Belt
The feed shaft, take-up shaft, and belt
(service part) are constructed as a single entity
(service part).
Mount the fixing upper cleaning belt by
reversing the steps used to remove it with the
following in mind:
1) Wind the cleaning belt around the cleaning
belt take-up shaft [1] two to three times.
2) Mount the feed shaft [2] of the cleaning
belt as shown.
3) Put the lever [3] of the fixing upper
cleaning belt length sensor inside.
4) Mount the take-up shaft of the cleaning
belt as shown.
5) Operate the cleaning belt feed lever [4]
10 to 20 times to remove all slack.
The cleaning belt can be-
come slack when you re-
lease the upper roller unit
during servicing work. At
the end of each servicing
job, be sure to operate the
cleaning belt drive assem-
bly 10 to 20 times by hand
to remove the slack.
8-22
COPYRIGHT © 2002 CANON INC.
(front)
CANON CLC1100/1130/1150/1160/1180 REV.1 FEB. 2002 PRINTED IN JAPAN (IMPRIME AU JAPON)
[1]
Figure 8-424 (rear view)
Figure 8-425
[4]
Figure 8-426
[2]
[3]