Frequency detection (n58)
Effective when either of output terminal function selection n40 is set to
"frequency detection" (setting: 4 or 5). "Frequency detection" turns ON
when output frequency is higher or lower than the frequency detection level
(n58).

• Frequency detection 1

(Output frequency Ä Frequency detection level n58)
(Set n40 to "4.")
• Frequency detection 2
(Output frequency à Frequency detection level n58)
(Set n40 to "5.")
52
FREQUENCY DETECTION
LEVEL [Hz] (n58)
OUTPUT
FREQUENCY
FREQUENCY
DETECTION
SIGNAL
RELEASE
WIDTH
+2Hz
OUTPUT
FREQUENCY
FREQUENCY
DETECTION
SIGNAL
RELEASE
WIDTH
–2Hz
ON
ON
ON
FREQUENCY
DETECTION
LEVEL (Hz)
(n58)