Preparing for Operation
S Set the rotation direction of the motor with n006 so that the motor will rotate in the set direction
when the reverse rotation command is input or set n006 so that the reverse rotation command will
be ignored.
n005

Forward/Reverse Rotation Selection

Setting range
0, 1
Set Values
Set value
0
The motor seen from the load side rotates counterclockwise.
1
The motor seen from the load side rotates clockwise.
Note The forward/reverse rotation selection setting (n005) is not initialized when the parameter initial-
ization is performed by setting the parameter write prohibit selection/parameter initialization
parameter (n001) to 6 or 7. To change this setting, change the value of the parameter directly.
n006

Reverse Rotation-inhibit Selection

Setting range
0, 1
Set Values
Set value
0
The motor can rotate reversely.
1
The motor cannot rotate reversely.
H Multi-function Input Selection (n035 to n039)
S Set n035 to n039 so that the Inverter can use multi-function input terminals 2 to 6 to perform the
following.
Three-wire sequential operation
Multi-step operation
Inching operation
Operation using acceleration time 2 and deceleration time 2
S Refer to 3-5-3 List of Parameters for details.
n035
Multi-function Input 1 (S2)
Setting range
0 to 24
n036
Multi-function Input 2 (S3)
Setting range
2 to 24
n037
Multi-function Input 3 (S4)
Setting range
2 to 24
n038
Multi-function Input 4 (S5)
Setting range
2 to 24
Unit
---
Description
Unit
---
Description
Unit
---
Unit
---
Unit
---
Unit
---
Chapter 3
Default setting
0
Default setting
0
Default setting
0
Default setting
2
Default setting
4
Default setting
9