Interpreting Can Lister Data - Agilent Technologies 4000 X-Series User Manual

Infiniivision 4000 x-series
Hide thumbs Also See for 4000 X-Series:
Table of Contents

Advertisement

23
CAN/LIN Triggering and Serial Decode
• The UTIL (bus load) indicator measures the percentage of time the bus
Example: If a data frame contains an active error flag, both the FRAMES
counter and the ERR counter will be incremented. If a data frame
contains an error that is not an active error it is considered a partial
frame and no counters are incremented.

Interpreting CAN Lister Data

In addition to the standard Time column, the CAN Lister contains these
columns:
• ID — frame ID.
• Type — frame type (RMT remote frame or Data).
• DLC — data length code.
• Data — data bytes.
394
is active. The calculation is done on 330 ms periods, approximately
every 400 ms.
Agilent InfiniiVision 4000 X-Series Oscilloscopes User's Guide

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents