Interpreting Arinc 429 Lister Data - Agilent Technologies 4000 X-Series User Manual

Infiniivision 4000 x-series
Hide thumbs Also See for 4000 X-Series:
Table of Contents

Advertisement

27
MIL-STD-1553/ARINC 429 Triggering and Serial Decode

Interpreting ARINC 429 Lister Data

In addition to the standard Time column, the ARINC 429 Lister contains
these columns:
• Label — the 5- bit label value in octal format.
• SDI — the bit values (if included in the word decode format).
• Data — the data value in binary or hex, depending on the base setting.
• SSM — the bit values (if included in the word decode format).
• Errors — highlighted in red. Errors can be Parity, Word, or Gap.
Aliased data is highlighted in pink. When this happens, decrease the
horizontal time/div setting and run again.