Skoda Octavia II 2004 Workshop Manual page 58

Hide thumbs Also See for Octavia II 2004:
Table of Contents

Advertisement

Octavia II 2004 ➤ , Octavia II 2010 ➤
Brake systems - Edition 11.2017
– Detach the control unit without tilting from the hydraulic unit
-arrow-.
– Carefully pull off all gasket rings from the valve domes of the
hydraulic unit.
WARNING
♦ On a disconnected control unit, the printed circuit board is
exposed.
♦ No humidity or dirt particles must penetrate into the inside
of the control unit.
♦ The hydraulic pump must not be separated from the hy‐
draulic unit.
– Cover the solenoid coils of the control unit with a non-fluffing
cloth.
After separating from the control unit and hydraulic unit use the
transport protection for valve domes.
5.5
Attaching control unit to hydraulic unit -
Left-hand drive
WARNING
Strong vibrations (e.g. fall, knock) can destroy the control unit.
The control unit must no longer be used.
The surfaces must be cleaned before assembling.
– Push all the gasket rings -A- a little over the valve domes.
– Position the control unit without tilting it onto the hydraulic unit.
Thus the gasket rings are brought into their end position.
– Screw hydraulic unit and control unit with the enclosed new
screws.
Note
A new control unit may only be installed on the same hydraulic
unit twice as a maximum to ensure that the elastic seal is still
leak-tight.
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
A control unit, which was once operational, must not be moun‐
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
ted a second time.
Specified torques:
Control unit to hydraulic unit 5.5 Nm