2 General Reset and Standard Start-Up

2.5 Memory configuration (as from SW 3)

2.5
Memory configuration (as from SW 3)
Standard values
for DRAM
Setting ranges
for DRAM
Note: The ranges cannot be set in software version 3.
SW 4.1 – 4.3
Part programs
32 kB to
UMS
0
IKA
0
0
FDD/MSD
0
Block buffer
0
0
Measured value
0
memory
0
Number of real axes
Data for extended
overstore
Number of measured
value buffers
Maximum
1 264 kB with 4 MB DRAM
3 264 kB with 8 MB DRAM SW 4.1–4.3
5 160 kB with 8 MB DRAM as from SW 4.4
Note as from SW 4:
For UMS at least the memory capacity specified by the WS 800 configuration
station must be entered (not the length of the UMS file transferred).
1) WS 800 can up to 1024
2-6
Softw. 3
1 MB Part prog.
512 kB
UMS
256 kB IKA
16 000 points
As from SW 4.4
2 760 kB
32 kB to
to
1 024 kB
0
to
1 024 kB
0
to
65 535 points
0
or
194/388 kB
0
to
2 760 kB
0
to
approx. 1 800
0
buffers
to
2 760 kB
0
to
700 000
0
meas. values
Siemens AG 2001 All Rights Reserved 6FC5197–jAA50
Softw. 4
4 MB DRAM
704 kB Part prog.
256 kB
UMS
64 kB IKA
4 000 points
240 kB
Block buffer
0 kB
Meas. value mem.
0 kB
FDD/MSD
4 920 kB
1)
to
2 760 kB
to
1 024 kB
to
65 535 points
or
194/388 kB
to
5 026 kB
to
approx. 3 450
buffers
to
2 760 kB
to
700 000
meas. values
04.96
09.95
Softw. 4
8 MB DRAM
704 kB Part prog.
256 kB
UMS
64 kB IKA
4 000 points
240 kB
Block buffer
0 kB
Meas. value mem.
0 kB
FDD/MSD
2 MB free (SW 4.1–4.3)
3.896 MB free (as from
SW 4.4)
or see below (maximum)
As from SW 5.4
Axes 15 to 30
16 kB
each
Axes 1 to 6
49 kB
each
Axes 1 to 30
4 byte
each
SINUMERIK 840C (IA)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611-d

Table of Contents