Siemens SINUMERIK 840C Installation Instructions Manual page 450

Siemens computer drive installation instructions
Hide thumbs Also See for SINUMERIK 840C:
Table of Contents

Advertisement

12.93
Description of user-programmable messages:
| n
| < n
(function no. 1)
act
min
The PLC status message is set when | n
Ramp-up complete (function no. 2)
The PLC status message is set when the actual speed value corresponds to the setpoint,
allowing for the tolerance band set in MD 27. This status message is not output when the
speed fluctuates as a result of load changes.
| M
| < M
(function no. 3)
d
dx
The PLC status message is set when | M
referred to the currently active speed-dependent torque limit. If the PLC status message
n
= n
is set when the speed setpoint is changed, then the PLC status message | M
act
set
< M
cannot be reset for at least 800 ms after the PLC status message n
dx
been reset.
| n
| < n
(function no. 4)
act
x
The PLC status message is set when | n
Motor overtemperature prewarning (function no. 5)
The PLC status message is set when the maximum motor temperature is reached (MD 63
for motor 1, MD 291 for motor 2). If the message does not disappear, then the drive
module is shut down with the "Motor overtemperature" alarm after the delay which can be
set in MD 65.
Heat sink overtemperature prewarning (function no. 6)
The PLC status message is set when the temperature switch of the main heat sink
responds. If the message does not disappear, then the drive module is shut down after
approximately 2 minutes with the "Heat sink overtemperature" alarm.
Variable relay function 1 (function no. 7)
MD 185
Address for monitoring 1
MD 186
Threshold for monitoring 1
MD 187
ON-delay monitoring 1
MD 188
Drop delay monitoring 1
MD 189
Hysteresis monitoring 1
Variable relay function 2 (function no. 8)
MD 190
Address for monitoring 2
MD 191
Threshold for monitoring 2
MD 192
ON-delay monitoring 2
MD 193
Drop delay monitoring 2
MD 194
Hysteresis monitoring 2
n
= n
(function no. 20)
act
set
The PLC status message is set when severe speed fluctuations occur as a result of load
changes.
©
Siemens AG 1992 All Rights Reserved
SINUMERIK 840C (IA)
7 Drive Machine Data (SIMODRIVE Drive MD)
7.1.2 MSD MD (data description - SW 3)
| < n
. Settable in MD 21.
act
min
| > M
. The percentage setting in MD 47 is
d
dx
| < n
. Settable in MD 23.
act
x
6FC5197- AA50
d
= n
has
act
set
0000 ... FFFFH
0000 ... FFFFH
0 ... 10.00 ms
0 ... 10.00 ms
0000 ... FFFFH
0000 ... FFFFH
0000 ... FFFFH
0 ... 10.00 ms
0 ... 10.00 ms
0000 ... FFFFH
7–35
|

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611-d

Table of Contents