Siemens SINUMERIK 840C Installation Instructions Manual page 263

Siemens computer drive installation instructions
Hide thumbs Also See for SINUMERIK 840C:
Table of Contents

Advertisement

6 NC Machine Data (NC MD), NC Setting Data (NC SD)
6.5 Spindle-specific MD (spindle data)
To activate feedforward control set option (6FC5 150-0AS02-0AA0).
The feedforward control factor is adapted to the machine stability and the resulting
acceleration/deceleration of the spindle. The degree to which the following error is reduced
depends on the feedforward factor.
A factor of 1000 reduces the following error almost to zero in the stationary state. However,
this setting will cause overshooting. If this is a problem you can enter a lower value and enter
the time constant in MD 467*.
See Section entitled "Functional Descriptions".
Note:
As from SW 4, for 8 gear stages
466*
Default value
Lower input limit
1
Active:
During position controlled operation (M19)
The number of axes and spindles can be increased by increasing the position control sampling
interval. Such increase will, however, impair the results produced by the controller. See
"Axes" for advantage.
The spindle-specific position controller sampling interval T
T
=MD 155
MD 168
MD 466*
LS
Notes
The position control sampling interval must be in an integer ratio to the selected inter-
polation clock pulse (MD 155).
If a C axis is assigned to the spindle via MD 461*, the position controller clock pulses of
spindle and C axis must coincide. The position controller clock pulse for the C axis is set
in MD 155, MD 160, MD 168, MD 1396*.
Permissible values:
1, 2, 4, 8, 16, 32, 64
467*
Default value
0
Active:
During position controlled operation (M19)
To avoid overshooting on spindles with feedforward control, insert a delay between the partial
setpoint and the position controller. This delay is set with this machine data.
_______
1)
The feed forward control can be switched off via PLC MD as from SW 2.
6–78
Position controller clock pulse spindle
Upper input limit
1
64
Time constant feedforward control
Lower input limit
Upper input limit
0
1 000 (as from SW 4)
©
Siemens AG 1992 All Rights Reserved
1)
Units
Multiple of position control-
ler basic clock pulse
is
LS
9 999
0.1 ms
6FC5197- AA50
SINUMERIK 840C (IA)
09.95
Active on
Power On
Active
Units

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611-d

Table of Contents