General Reset (Up To Sw 2) - Siemens SINUMERIK 840C Installation Instructions Manual

Siemens computer drive installation instructions
Hide thumbs Also See for SINUMERIK 840C:
Table of Contents

Advertisement

09.95
2.9

General reset (up to SW 2)

Fig. 2.4
The start-up sequence is obligatory since the NC and PLC machine data must
have been entered before the user memory is formatted and the part program
memory is deleted.
"DEL./LOAD MACH. DATA": The delete/load screenform is displayed.
DEL./LOAD
MACH. DATA
"DELETE NC-MD": NC-MD are deleted and formatted.
DELETE
NC-MD
or
LOAD NC-MD
LOAD NC-MD
T VERSION
M VERSION
If files exist on hard disk in the DIAGNOSIS, NC DATA MANAGEMENT, PC
LOAD
DATA MANAGEMENT areas, softkey "LOAD" can be used to load these files from
the hard disk to the NCK-CPU.
"DELETE PLC-MD": PLC-MD are deleted and formatted.
DELETE
PLC-MD
"LOAD PLC-MD": The default PLC-MDs are loaded.
LOAD
PLC-MDs are not transferred to the PLC until the general reset mode is exited.
PLC-MD
Note
For selecting data management, press the area switchover key, "DIAGNOSIS"
and "SHIFT" + "RECALL" in the General reset selection form.
Siemens AG 2001 All Rights Reserved 6FC5197–jAA50
SINUMERIK 840C (IA)
MACHINE
PARAMETER PROGRAMM.
JOG
PROGRAM RESET
Installation mode general reset
Delete machine data, load standard values
Initialize NC memory/user data, part program
Initial clear PLC memory/load basic program
Display NC alarms
Conclude installation, return to normal operation,
disable password (switchkey on central service board
module to 0!)
Initial
Initial clear
Del/load
MD
memory
"NC-MD LOAD T VERSION" or "NC-MD LOAD M VERSION":
Standard MD for T or M version are loaded.
2 General Reset and Standard Start-Up
2.9 General reset (up to SW 2)
SERVICES
PLC
DIAGNOSIS
16:38
M. No. :1
Chann :1
Display
End
NC alarms
start-up