Siemens SINUMERIK 840C Installation Instructions Manual page 538

Siemens computer drive installation instructions
Hide thumbs Also See for SINUMERIK 840C:
Table of Contents

Advertisement

07.97
1425
Default value
0.0
Selection of a filter in the speed feedforward control channel to simulate the calculation dead
time of the current control loop. Effective only when the speed/torque feedforward control
function is active.
MD 1004, bit 0.
Machine data MD 1425 (input: Calculation dead time referred to speed controller cycle) allows
the setpoint response in the speed feedforward control channel of the speed controller to be
adapted to the controlled system performance of the closed speed control loop, thus ensuring
symmetrization of the higher-level speed control loop.
1426
Default value
20.0
Input of threshold value for the tolerance band of PLC status signals "n
"Power-up procedure completed". The signal "n
value enters the tolerance band set around the speed setpoint and remains there for a period
corresponding to the delay time set in MD 1427. The signal is deactivated as soon as the
actual speed leaves the tolerance band. The delay time is applied only if the ramp-function
generator executes the edge change active passive.
The "Power-up procedure completed" signal is activated at the same time as the "n
signal; however, it is locked in the active state until the next setpoint change, even if the actual
speed value leaves the tolerance band. The "Power-up procedure completed" signal is
deactivated immediately if the setpoint changes.
Functionality in as from SW 6
As long as the control signals that the speed setpoint is being adjusted, the tolerance band is
"frozen" at the last setpoint value. The signal is cleared when the setpoint leaves the tolerance
band. It therefore does not drop out when the setpoint jumps within a tolerance range.
See also ramp-up measurement, MD 1723: ACTUAL_RAMP_TIME
1427
Default value
200.0
Input of delay time for response of n
(MD 1426).
1428
Default value
90.0
Input of setting value (specified as percentage) for machine data "Threshold torque". This
machine data defines the torque limit value at which the message "M
The input value is referred to the presently valid torque limit value. Analogously to this value,
the maximum permissible torque is dependent on the working point above the rated speed
value in the constant power (field weakening) range, thus resulting in a threshold torque curve
which drops in relation to the 1/n function or from the breakdown torque 1/n2.
©
Siemens AG 1992 All Rights Reserved
SINUMERIK 840C (IA)
Symmetr.calc.deadtime I-controller
Lower input limit
Upper input limit
0.0
Tolerance band for n
= n
set
Lower input limit
Upper input limit
0.0
= n
set
act
Delay time n
= n
set
act
Lower input limit
Upper input limit
0.0
= n
signal depending on tolerance band
set
act
Threshold torque M
Lower input limit
Upper input limit
0.0
6FC5197- AA50
7 Drive Machine Data (SIMODRIVE Drive MD)
7.3.2 Drive MD (data description)
1.0
signal
act
10 000.0
rev/min
= n
" and
act
min
" is activated if the actual speed
signal
500.0
dx
100.0
< M
" is deactivated.
d
dx
Active
at once
Units
Active
at once
Units
= n
"
set
act
Active
at once
Units
ms
Active
at once
Units
%
7–123

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611-d

Table of Contents