7 Drive Machine Data (SIMODRIVE Drive MD)
7.1.2 MSD MD (data description - SW 3)
182
Default value
Output of minimum value of a previously defined variable (see MD 181). The value is displayed
in hexadecimal format.
183
Default value
Output of maximum value of a previously defined variable (see MD 181). The value is
displayed in hexadecimal format.
185
Default value
0C06
Input of address 1 to be monitored for variable relay function 1.
186
Default value
0000
Input of threshold value 1 of address 1 to be monitored for variable relay function 1.
187
Default value
0
Input of ON-delay 1 of address 1 to be monitored for variable relay function 1.
188
Default value
0
Input of drop delay 1 of address 1 to be monitored for variable relay function 1.
7–24
Minimum value min/max memory
Lower output limit
Upper output limit
0000
Maximum value min/max memory
Lower output limit
Upper output limit
0000
Address for monitoring 1
Lower input limit
Upper input limit
0000
Threshold for monitoring 1
Lower input limit
Upper input limit
0000
ON-delay monitoring 1
Lower input limit
Upper input limit
0
Drop delay monitoring 1
Lower input limit
Upper input limit
0
©
Siemens AG 1992 All Rights Reserved
Units
Hex
Units
Hex
Units
FFFF
Hex
Units
FFFF
Hex
Units
10.00
s
Units
10.00
s
6FC5197- AA50
SINUMERIK 840C (IA)
10.94
Active
at once
Active
at once
Active
at once
Active
at once
Active
at once
Active
at once