Siemens SINUMERIK 840C Installation Instructions Manual page 252

Siemens computer drive installation instructions
Hide thumbs Also See for SINUMERIK 840C:
Table of Contents

Advertisement

09.95
Voltage
[volts]
U
10
max
MD 448*
MD 411*
MD 412*
If 3rd gear has been engaged, the new S value must be lower than the contents of MD 413* in
order for the NC to initiate a gear change.
U
: maximum setpoint speed voltage (MD 468*)
max
419*-426*
Acceleration time constant for eight gears
Default value
800
Gear
1
NC MD
419*
The control provides the setpoint for acceleration in the form of a ramp that is based on the
contents of these MD. The MD thus act as variable ramp-function generators. They are set by
measuring the interval from zero speed to maximum speed for each gear. NC MD 419*-426*
can be set to zero when the drive actuator is equipped with an integrated ramp-function
generator.
Notes:
There are two acceleration time constants for every stage:
Acceleration time constant without position controller (MD 419* to 426*)
Acceleration time constant without position controller (MD 478* to 485*)
In control mode the time constants are used without position control.
In positioning mode the time constants are used with position control.
©
Siemens AG 1992 All Rights Reserved
SINUMERIK 840C (IA)
6 NC Machine Data (NC MD), NC Setting Data (NC SD)
MD 403*
MD 404*
MD 413*
Lower input limit
Upper input limit
+0
2
3
4
420*
421*
422*
6FC5197- AA50
6.5 Spindle-specific MD (spindle data)
MD 405*
Speed [rev/min]
Units
50 000
1 ms
5
6
7
423*
424*
425*
Active on
NC Stop
8
426*
6–67

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611-d