6 NC Machine Data (NC MD), NC Setting Data (NC SD)
6.7.1 Axis-specific MD bits 2 (axial bits 2)
NC MD
7
1828*
NC MD 1828* bit 1:
This bit is only used for linear axes with ENDAT absolute encoders.
Bit 1 Bit 1=1 Linear scale not available. Maximum traversing range of this axis is then + / -
half of the maximum traversing range of the absolute encoder, symmetrical
around the zero position.
Bit 1=0 Linear scale available. The traversing range of this axis does not have to be
set symmetrically around the zero position. The maximum traversing range is
calculated to: + / - the traversing range of the absolute encoder/8* MD 1264*.
Bit 0 Bit 0=1 Extended parameter set switchover
Bit 0=0 Gear stages/parameter set switchover as in SW 1 - 3
Parameter set switchover is only possible with the option bit.
Active: After Power On
NC MD
7
1832*
(from
SW 6.3)
Bit 4 Bit 4=1 This axis is an actual value reading axis at the 2nd measuring system
connection (NC MD 1388*). The restrictions for reading axes therefore apply.
Bit 4=0 This axis has unrestricted use of the 2nd measuring system connection (NC
MD 1388*)
Bit 3 Bit 3=1 This axis is an actual value reading axis at the 1st measuring system
connection (NC MD 200*). The restrictions for reading axes therefore apply.
Bit 3=0 This axis has unrestricted use of the 1st measuring system connection (NC
MD 200*).
Bit 2 Bit 2=1 Multiple assignment of the 2nd measuring system connection of this axis (NC
MD 1388*) is permitted with digital drives. When using this measuring system
connection only one of these axes must not have a Bit 4 setting under MD
1832*. Bit 4 must be set on all others.
Bit 2=0 Multiple assignment of the 2nd measuring system connection of this axis (NC
MD 1388*) is not permitted.
Bit 1 Bit 1=1 Multiple assignment of the 1st measuring system connection of this axis (NC
MD 200*) is permitted with digital drives. When using this measuring system
connection only one of these axes must not have a Bit 3 setting under MD
1832*. Bit 3 must be set on all others.
Bit 1=0 Multiple assignment of the 1st measuring system connection of this axis (NC
MD 200*) is not permitted.
Bit 0 Bit 0=1 The new PT2 contour monitoring is activated even if 0 is set under NC MD
3420*. By entering a compensation value between 1 and 600 under NC MD
3420*, the PT2 following error model will be calculated according to this
compensation value.
Bit 0=0 The existing contour monitoring is activated as long as 0 is set under NC MD
3420*. By entering a compensation value between 1 and 600 under NC MD
3420*, this will activate the improved PT1 contour monitoring.
Active:
6–190
Bit No.
6
5
4
Bit No.
6
5
4
Actual value
reading axis
2nd measur-
ing system
After Power On
©
Siemens AG 1992 All Rights Reserved
3
2
1
Linear scale
(as from
SW 6.3)
3
2
1
Actual value
Multiple
Multiple
reading axis
assignment
assignment
1st measur-
2nd measur-
1st measur-
ing system
ing system
ing system
SINUMERIK 840C (IA)
01.99
0
Extended
parameter
set switch-
over (as from
SW 4)
0
PT2 contour
monitoring
active
6FC5197- AA50