Siemens SINUMERIK 840C Installation Instructions Manual page 564

Siemens computer drive installation instructions
Hide thumbs Also See for SINUMERIK 840C:
Table of Contents

Advertisement

04.96
Diagnostic function "Voltage-controlled V
A voltage-controlled operating mode (V/F mode) is applied in order to diagnose speed or
current sensor faults. In this operating mode, voltages V
frequency are input as controlled quantities. As a result of the transformation (d/q
R/S/T), a constantly changing rotating field is applied to the motor via the trigger
equipment ASIC, making it possible to attain a speed within the n
operation. The system oscillates at higher speeds.
Corresponding machine data are as follows:
Motor frequency V/F mode (MD 1660)
Ratio V/F during V/F mode (MD 1661)
If MD 1661 is set to an excessively high value, the resulting I
temperature rise in the drive and an additional increase in oscillation at high speeds.
If MD 1661 is set to a very low value, the resulting I
impossible for the drive to follow the specified frequency.
An operating status message is transmitted to the SERVO by means of bit 28 in the status
word.
The current and speed controllers are not active in V/F mode
Unfavourable parameter settings may cause excessively high currents to occur in V/F
mode; the existing current monitoring function therefore remains active.
1651
Default value
0
Input of signal number of memory location to be monitored by the min/max memory function.
Caution:
This machine data is relevant only for Siemens-internal purposes and must not be altered.
©
Siemens AG 1992 All Rights Reserved
SINUMERIK 840C (IA)
operation" (up to SW 4)
q
q
Signal number min/max memory
Lower input limit
Upper input limit
0
6FC5197- AA50
7 Drive Machine Data (SIMODRIVE Drive MD)
7.3.2 Drive MD (data description)
and V
= 0 as well as a
q
d
/5 range in V/F
rated
current at n
/5 causes a
d
rated
current value is too low, making it
Units
100
Active
at once
7–149

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611-d

Table of Contents