Siemens SINUMERIK 840C Installation Instructions Manual page 554

Siemens computer drive installation instructions
Hide thumbs Also See for SINUMERIK 840C:
Table of Contents

Advertisement

09.95
1613
Default value
0100/FFFF
Input bit field for switching over the appropriate 611D reset alarm. It is possible to select one of
two shutdown reactions, i.e. pulse disable (bit = 1) or controller disable (bit = 0 ˆ = nset = 0
ˆ = generator-mode braking), i.e. when the pulse disable reaction is selected, the controller
disable reaction is deactivated. The default setting is dependent on the motor type (FDD =
0100, MSD = FFFF) and is parameterized by the drive configuration during start-up.
Note:
The MSD default setting (FFFF) must be selected when the FDD H option is used.
611D messages can be switched to reset alarms via MD 1012 bit 4.
Caution:
The alarms may be deactivated or concealed through machine data MD 1601 - Concealable
alarms (reset), i.e. they may be inactive.
Value table:
Bit 0
Pulse disable, configuration error
Bits 1-7
Not assigned
Bit 8
Reserved
Bit 9
Pulse disable, encoder limit frequency
Bits 10-12
Not assigned
Bit 13
Pulse disable abs. motor encoder
temperature
Bit 14
Pulse disable on motor temperature
warning
Bit 15
Not assigned
1615
Default value
2.0
Load test: Setting the tolerance range for concentricity monitoring. If the tolerance range is
violated (underrange or overrange) by the actual speed, counter "Diagnostics concentricity
monitoring" MD 1724 is incremented.
1620
Default value
0000
Input bit field for controlling the variable message function.
©
Siemens AG 1992 All Rights Reserved
SINUMERIK 840C (IA)
Config. shutdown react. RESET alarms
Lower input limit
0000
Concentricity monitoring tolerance
Lower input limit
0.0
Bits variable message function
Lower input limit
0000
6FC5197- AA50
7 Drive Machine Data (SIMODRIVE Drive MD)
7.3.2 Drive MD (data description)
Upper input limit
FFFF
1 = on
0 = off
1 = on
0 = off
1 = on
0 = off
1 = on
0 = off
Upper input limit
100.0
Upper input limit
FFFF
Active
at once
Units
Hex
Active
at once
Units
rpm
Active
at once
Units
Hex
7–139

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611-d

Table of Contents