07.97
1102
Default value
0
Input of motor order number (machine-readable product designation for Siemens motors). This
number is transferred to the drive in the form of a motor code number. The user does not
need to input a value (see also MD 1106). The following motor data are automatically
transferred from an internal motor table by means of the motor code number:
MD 1103: Motor rated current (FDD/MSD)
MD 1104: Maximum motor current (FDD)
MD 1112: Pole pair number of motor (FDD)
MD 1113: Torque constant (FDD)
MD 1114: Voltage constant (FDD)
MD 1115: Armature resistance (FDD)
MD 1116: Armature inductance (FDD)
MD 1117: Motor moment of inertia (FDD/MSD)
MD 1118: Motor zero-speed current (FDD)
MD 1130: Motor rated power (MSD)
MD 1132: Motor rated voltage (MSD)
MD 1134: Motor rated frequency (MSD)
MD 1135: Motor no-load voltage (MSD)
MD 1136: Motor no-load current (MSD)
MD 1137: Stator resistance cold (MSD)
MD 1138: Rotor resistance cold (MSD)
MD 1139: Stator leakage reactance (MSD)
MD 1140: Rotor leakage reactance (MSD)
MD 1141: Main field reactance (MSD)
MD 1142: Starting speed field weakening (MSD)
MD 1143: Upper speed L
MD 1144: Gain factor L
MD 1146: Motor maximum speed (FDD/MSD)
MD 1400: Motor rated speed (FDD/MSD)
MD 1602: Maximum motor temperature (FDD/MSD)
Note:
If a valid motor order number cannot be entered in this machine data (e.g. for a motor make
other than Siemens), then all these machine data must be entered manually.
Motor table: MSD motors
Order no.
Rated
speed
n
rated
rev/min
1PH6101-4NF4- x
1500
1PH6101-4NG4- x
2000
1PH6103-4NF4- x
1500
1PH6103-4NG4- x
2000
1PH6105-4NF4- x
1500
1PH6105-4NG4- x
2000
©
Siemens AG 1992 All Rights Reserved
SINUMERIK 840C (IA)
Motor code number
Lower input limit
0
characteristic (MSD)
h
characteristic (MSD)
h
Motor
Order no.
code no.
in
101
1PH6107-4NF4- x
102
1PH6107-4NG4- x
103
1PH6131-4NF4- x
104
1PH6131-4NG4- x
105
1PH6133-4NF0- x
106
1PH6133-4NF4- x
6FC5197- AA50
7 Drive Machine Data (SIMODRIVE Drive MD)
7.3.2 Drive MD (data description)
Upper input limit
65 535
Rated
speed
n
in
rated
rev/min
1500
2000
1500
2000
1500
1500
Active on
Power On
Units
Motor
code no.
107
108
109
110
111
112