5.9.7 Reinstallation of existing and new drive components using the existing drive files (TEA3)

5.9.7
Reinstallation of existing and new drive components using the
existing drive files (TEA3)
Application
You require a two-tier configuration, i.e. a 2nd module group is to be added.
TEA3 user files already exist for the individual modules and motors.
Procedure
Select the File functions softkey in the configuring display and then operate the
(1st method)
Load from disk softkey. A menu bar appears in which you enter the existing
TEA3 files together with the file names and then select the Config area with the
toggle key.
Operate the Load start softkey. The data are loaded into the drive. Confirm these
settings with the Accept conf + NCKP0 softkey.
Fig. 5.23
Procedure 1
Again select the drive configuration display and the File functions softkey. Using
(2nd method)
the Load from disk softkey, load the TEA3 files in the Drives area into the drive
using the Load start softkey. Confirm this setting with the Accept all + NCKP0
softkey.
Siemens AG 2001 All Rights Reserved 6FC5197–jAA50