Siemens SINUMERIK 840C Installation Instructions Manual page 398

Siemens computer drive installation instructions
Hide thumbs Also See for SINUMERIK 840C:
Table of Contents

Advertisement

07.97
60006
Number of parameters per tool as from SW 4
Default value
10
819 tools with 10 parameters each corresponds to 32760 bytes = approx. 32 KB memory.
The upper input limit depends on the NCK memory capacity (4 or 8 MB memory).
Note:
The standard tool management (FB package 1) still uses the values in MD 5019,
bit 0 and 1.
60007
Number of channel-spec. R parameters as from SW 4
Default value
700
See functional description of "Flexible memory configuration".
60008
Number of central R parameters as from SW 4
Default value
600
The upper input limit depends on the number of tools (see MD 60005/60006) and the number
of channel-specific R parameters (see MD 60007).
See functional description of "Flexible memory configuration".
60009
Free remaining memory D-RAM as from SW 4
Default value
0
Machine data reserved by the system.
60010
Free remaining memory S-RAM as from SW 4
Default value
0
Machine data reserved by the system.
©
Siemens AG 1992 All Rights Reserved
SINUMERIK 840C (IA)
6 NC Machine Data (NC MD), NC Setting Data (NC SD)
Lower input limit
Upper input limit
0
Lower input limit
Upper input limit
0
Lower input limit
Upper input limit
0
Lower input limit
Upper input limit
Lower input limit
Upper input limit
6FC5197- AA50
6.10 MDs for flexible memory configuration
"Reconfigure
Units
10
1 TO
32
"Reconfigure
Units
700
1 R parameter
"Reconfigure
Units
9 300
1 R parameter
"Reconfigure
Units
Byte
"Reconfigure
Units
Byte
Active
after SK
memory"
Active
after SK
memory"
Active
after SK
memory"
Active
after SK
memory"
Active
after SK
memory"
6–213