12.93
222
Default value
Depends on motor
Input of motor rated voltage as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 238).
223
Default value
Depends on motor
Input of motor rated speed as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 238).
224
Default value
Depends on motor
Input of motor rated frequency as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 238).
225
Default value
Depends on motor
Input of motor no-load voltage as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 238).
226
Default value
Depends on motor
Input of motor no-load current as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 238).
227
Default value
Depends on motor
Input of stator resistance (cold) as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 238).
©
Siemens AG 1992 All Rights Reserved
SINUMERIK 840C (IA)
Motor rated voltage motor 2
Lower input limit
Upper input limit
0
Motor rated speed motor 2
Lower input limit
Upper input limit
0
Motor rated frequency motor 2
Lower input limit
Upper input limit
0
Motor no-load voltage motor 2
Lower input limit
Upper input limit
0
Motor no-load current motor 2
Lower input limit
Upper input limit
0
Stator resistance cold motor 2
Lower input limit
Upper input limit
0
6FC5197- AA50
7 Drive Machine Data (SIMODRIVE Drive MD)
7.1.2 MSD MD (data description - SW 3)
Units
500.0
Units
4 096
1/min
Units
409.6
Hz
Units
500.0
Units
200.0
Units
32 767
m
Active on
Power On
V
Active on
Power On
Active on
Power On
Active on
Power On
V
Active on
Power On
A
Active on
Power On
7–31