6 NC Machine Data (NC MD), NC Setting Data (NC SD)
6.9.1 MDs for collision monitoring
Protection zone reference point vector FP1
3816*
Default value
0
Protection zone reference point vector FP1
3820*
Default value
0
*=Protection zone number
1st protection zone=0
2nd protection zone=1 to
32nd protection zone=31
The dimensions of protection zone Sn are entered in the following protection-zone-specific
machine data:
3824*
Default value
0
3828*
Default value
0
3832*
Default value
0
*=Protection zone number
1st protection zone=0
2nd protection zone=1 to
32nd protection zone=31
Protection zone dimensions in 2 coordinates not equal to 0:
Two-dimensional monitoring only in the plane described by the coordinates in question (see:
Definition of protection zone planes). In the third coordinate the protection zone is understood
as infinite.
6–206
Y coordinate (as from SW 6)
Lower input limit
0
Z coordinate (as from SW 6)
Lower input limit
0
Dimension X coordinate (as from SW 6)
Lower input limit
0
Dimension Y coordinate (as from SW 6)
Lower input limit
0
Dimension Z coordinate (as from SW 6)
Lower input limit
0
©
Siemens AG 1992 All Rights Reserved
Upper input limit
99 999 999
Upper input limit
99 999 999
Upper input limit
99 999 999
Upper input limit
99 999 999
Upper input limit
99 999 999
SINUMERIK 840C (IA)
07.97
POWER ON
Units
MS
POWER ON
Units
MS
POWER ON
Units
MS
POWER ON
Units
MS
POWER ON
Units
MS
6FC5197- AA50