6 NC Machine Data (NC MD), NC Setting Data (NC SD)
6.10 MDs for flexible memory configuration
60003
Default value
0
If MD 60003 and/or 60004 are set to 1 the memory for the drive software is automatically set
to 192/384 Kbytes (compatible memory requirement). The memory size can also be altered by
changing MD 60014 (toggling).
The following toggling options are available:
MD 60003 and MD 60004=0
MD 60003 or MD 60004=1
MD 60003 and MD 60004=1
Note:
See also function "Flexible memory configuration".
60004
Memory for drive software for FDD as from SW 4
Default value
0
If an area of the memory is reserved for FDD drive software, 194 KB memory is occupied.
Zero means no memory. The memory is only required for digital drives. The software only
loads the FDD software if the memory has been reserved for it.
Note:
The meaning of this machine data changes as from SW 6.
60004
Default value
0
See machine data 60003.
60005
Default value
819
The upper input limit depends on the number of parameters per tool (see MD 60006) and the
number of R parameters (see MD 60007/60008).
Note:
The standard tool management (FB package 1) still uses the values in MD 5019,
bit 0 and 1.
6–212
Load MS drive software (as from SW 6)
Lower input limit
0
MD 60014
0 Kbytes
MD 60014
288 192 Kbytes
MD 60014
576 384 192 Kbytes
Lower input limit
0
Load FD drive software (as from SW 6)
Lower input limit
0
Number of tools as from SW 4
Lower input limit
1
©
Siemens AG 1992 All Rights Reserved
Upper input limit
1
Upper input limit
1
Upper input limit
1
Upper input limit
1 637
SINUMERIK 840C (IA)
01.99
POWER ON
Units
Active
after SK
"Reconfigure
memory"
Units
POWER ON
Units
Active
after SK
"Reconfigure
memory"
Units
1 TO