12.93
Bit 0
Internal error cannot be concealed
Bit 1
Not assigned
Bit 2
Measuring circuit error, phase current R
Bit 3
Measuring circuit error, phase current S
Bit 4
Measuring circuit error, position measuring system motor
Bit 5
Measuring circuit error, position measuring system motor (absolute track optical
encoder)
Bits 6-7
Not assigned
Bit 8
Zero monitoring position (zero mark) measuring system motor
Bits 9-14
Not assigned
Bit 15
Temperature power section shutdown
Note:
Power on 611D alarms can be acknowledged only via a hardware reset.
1601
Default value
0000
This machine data allows reset 611D alarms to be concealed or disabled. The alarm is active if
the appropriate bit = 0. All 611D alarms are activated as standard.
Bit 0
Configuration error cannot be concealed
Bits 1-7
Not assigned
Bit 8
Speed controller at fixed stop
Bits 9-13
Not assigned
Bit 14
Shutdown motor overtemperature
Bit 15
Not assigned
Note:
Reset 611D alarms can be acknowledged via a software reset.
1602
Default value
120
Input of maximum permissible motor temperature. The temperature is detected by appropriate
sensors and evaluated in the drive. A message is transferred to the SERVO when the warning
limit is reached.
©
Siemens AG 1992 All Rights Reserved
SINUMERIK 840C (IA)
Concealable reset 611D alarms
Lower input limit
Upper input limit
0000
Motor temperature warning limit
Lower input limit
Upper input limit
0
6FC5197- AA50
7 Drive Machine Data (SIMODRIVE Drive MD)
7.2.2 FDD MD (data description - SW 3)
Units
FFFF
Hex
Units
200
°C
Active
at once
Active
at once