7 Drive Machine Data (SIMODRIVE Drive MD)
7.3.2 Drive MD (data description)
Format of power section code number:
Value table:
Code
Drive type
6
7
8
9
A
B
C
D
11
12
14
16
17
19
1A
28
1107
Default value
200.0
Input of maximum permissible current of power section. This machine data is automatically
parameterized for Siemens power sections by the machine data "Power section code"
(MD 1106).
Caution:
This data serves as the basis for normalizing the current actual value sensor and must not be
changed by the user after automatic presetting of its values.
7–88
Current
MSD
24/32/32 A
MSD
30/40/51 A
MSD
45/60/76 A
MSD
60/80/102 A
MSD
85/110/127 A
MSD
120/150/193 A
MSD
200/250/257 A
MSD
45/60/76 A
FDD
3/6 A
FDD
5/10 A
FDD
9/18 A
FDD
18/36 A
FDD
28/56 A
FDD
56/112 A
FDD
70/140 A
FDD
140/210 A
Transistor limit current, power section
Lower input limit
1.0
©
Siemens AG 1992 All Rights Reserved
PS
50 A
80 A
120 A
160 A
200 A
300 A
400 A
108 A
8 A
15 A
25 A
50 A
80 A
160 A
200 A
400 A
as from SW 4.1
Upper input limit
500.0
SINUMERIK 840C (IA)
07.97
Comments
Active on
Power On
Units
A