09.95
5.8.4
File functions (sequence of operation – as from SW 3)
5.8.4.1 1st level: File functions
Explanation
Press the Diagnosis, Start-up, Machine data and File functions softkeys to call
the 1st level file functions display.
Fig. 5.13
A new file can be created. You are prompted to enter a name.
Edit
New
Select a file that already exists from the manufacturer (Siemens) or user field.
Edit
Only the BOOT file cannot be selected. It is a special file required for the drive
installation. The selected file is displayed in the data record field in the
configuration display.
Files already existing can be deleted together with their contents in the display
Delete
field. First select the file to be deleted. Caution, if you select the BOOT file in the
Siemens branch (above) you will delete its contents!
Siemens AG 2001 All Rights Reserved 6FC5197–jAA50
SINUMERIK 840C (IA)
5.8.4 File functions (sequence of operation – as from SW 3)
Machine
data
5 Machine Data Dialog (MDD – as from SW 3)
Diagnosis
Start-up
File
functions
5–37