Siemens SINUMERIK 840C Installation Instructions Manual page 447

Siemens computer drive installation instructions
Hide thumbs Also See for SINUMERIK 840C:
Table of Contents

Advertisement

7 Drive Machine Data (SIMODRIVE Drive MD)
7.1.2 MSD MD (data description - SW 3)
228
Default value
Depends on motor
Input of rotor resistance (cold) as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 238).
229
Default value
Depends on motor
Input of stator leakage reactance as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 238).
230
Default value
Depends on motor
Input of rotor leakage reactance as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 238).
231
Default value
Depends on motor
Input of magnetizing reactance as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 238).
232
Default value
Depends on motor
Input of the upper speed limit for the X
the motor data sheet (non-Siemens motor) or automatic parameterization using machine data
"Motor code number" (MD 238). In the field-weakening range, the magnetizing reactance X
increases linearly from the saturated value at the speed at which field weakening begins to the
unsaturated value at the upper limit speed of the X
7–32
Rotor resistance cold motor 2
Lower input limit
0
Stator leakage reactance motor 2
Lower input limit
0
Rotor leakage reactance motor 2
Lower input limit
0
Magnetizing reactance motor 2
Lower input limit
0
Upper speed X
characteristic motor 2
h
Lower input limit
100
characteristic (magnetizing reactance) as specified on
h
characteristic (see diagram MD 175).
h
©
Siemens AG 1992 All Rights Reserved
Upper input limit
32 767
Upper input limit
32 767
Upper input limit
32 767
Upper input limit
65 535
Upper input limit
10 000
SINUMERIK 840C (IA)
12.93
Active on
Power On
Units
m
Active on
Power On
Units
m
Active on
Power On
Units
m
Active on
Power On
Units
m
Active on
Power On
Units
rev/min
h
6FC5197- AA50

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611-d

Table of Contents