Wiring Of Pulser Input Connector - Panasonic FP? Positioning Unit RTEX Technical Manual

Automation controls
Table of Contents

Advertisement

3.3 Wiring of Pulser Input Connector

Supplied connector/Suitable wire
A connector of the spring connection type is used. Use the following suitable wires for the wiring.
Supplied connector socket
The connector socket manufactured by Phoenix Contact Co. should be used.
Manufacturer
Phoenix Contact Co.
Suitable wires (strand wire)
Suitable wires
AWG# 28 to 20
Pole terminal with a compatible insulation sleeve
If a pole terminal is being used, the following models manufactured by Phoenix Contact Co. should be
used.
Manufacturer
Phoenix Contact Co.
Pressure welding tool for pole terminals
Manufacturer
Phoenix Contact Co.
For tightening the connector
For inserting the wires, use a screwdriver (Phoenix contact Co., Product No. 1205202) with a blade size
of 0.4 × 2.0 (Part No. SZS 0,4×2,0).
3-4
Number of pins
Part No.
12 pins
FK-MC0, 5/12-ST-2,5
Tightening torque
0.14 to 0.5 mm
Cross-sectional area
2
(mm
)
0.25
0.34
0.50
Part No.
CRIMPFOX 10S
2
Size
AWG #24
A 0, 25-7
AWG #22
A 0, 34-7
AWG #20
A 0, 5-6
Product No.
1212045
Product No.
1881422
Part No.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fp2 positioning unit rtex

Table of Contents