Panasonic FP? Positioning Unit RTEX Technical Manual page 233

Automation controls
Table of Contents

Advertisement

17.4.9 Positioning Control Area
This is the area to set the repeat count of the positioning control to be started by axis.
-
The positioning unit repeats the started positioning control for the specified repeat count and then
-
completes the operation. The repeat count is changed to the default value on completion of the
operation.
Offset
Bank
Name
address
Positioning
108H
repeat count of
axis 1
Positioning
109H
repeat count of
axis 2
Positioning
10AH
repeat count of
axis 3
Positioning
10BH
repeat count of
axis 4
00H
Positioning
10CH
repeat count of
axis 5
Positioning
10DH
repeat count of
axis 6
Positioning
10EH
repeat count of
axis 7
Positioning
10FH
repeat count of
axis 8
Descriptions
Stores the number of times for repeating the
operation starting from the position control starting
table number of the first axis until the E point.
When 255 is stored, the positioning control is
repeated unlimitedly until the operation is stopped.
Stores the number of times for repeating the
operation starting from the position control starting
table number of the second axis until the E point.
When 255 is stored, the positioning control is
repeated unlimitedly until the operation is stopped.
Stores the number of times for repeating the
operation starting from the position control starting
table number of the third axis until the E point.
When 255 is stored, the positioning control is
repeated unlimitedly until the operation is stopped.
Stores the number of times for repeating the
operation starting from the position control starting
table number of the fourth axis until the E point.
When 255 is stored, the positioning control is
repeated unlimitedly until the operation is stopped.
Stores the number of times for repeating the
operation starting from the position control starting
table number of the fifth axis until the E point.
When 255 is stored, the positioning control is
repeated unlimitedly until the operation is stopped.
Stores the number of times for repeating the
operation starting from the position control starting
table number of the sixth axis until the E point.
When 255 is stored, the positioning control is
repeated unlimitedly until the operation is stopped.
Stores the number of times for repeating the
operation starting from the position control starting
table number of the seventh axis until the E point.
When 255 is stored, the positioning control is
repeated unlimitedly until the operation is stopped.
Stores the number of times for repeating the
operation starting from the position control starting
table number of the eighth axis until the E point.
When 255 is stored, the positioning control is
repeated unlimitedly until the operation is stopped.
Default
Setting
Unit
value
range
0
0 to 255
times
0
0 to 255
times
0
0 to 255
times
0
0 to 255
times
0
0 to 255
times
0
0 to 255
times
0
0 to 255
times
0
0 to 255
times
17-19