Sample program
Precautions on programming
• To start the interpolation control, turn on the positioning start contact of the axis with the smallest
number in the same group.
• The values of the X-axis auxiliary point and Y-axis auxiliary point are invalid for the linear interpolation.
• When setting the long axis speed, the composite speed is faster than the long axis speed.
• If any value such as a movement amount, acceleration time, deceleration time or target speed is out of
the specified range, a setting value error will occur when the position control starts.
• The number of the startup contact and flag varies depending on the number of axes and the installation
position.
• The specified slot number varies depending on the installation position of the unit.
8-24